CD6 multi-parameter gas detector

Product Details

CD6 multi-parameter gas detector meets ib protection level of intrinsically safe type, and is applicable to the detection of methane, carbon monoxide, oxygen, hydrogen sulfide gas parameter in coal mine hazard zone 1 as well as the detection of temperature, relative humidity. The detected data can be read, stored through the USB port or transmitted through a wireless Wi-Fi network.

 

Main Performance

  • The detector adopts special detection mechanism and applies software bridge detection and real-time dynamic software temperature compensation technology, there is no zero deviation problem, with little drift, high sensitivity, fine linearity and repeatability, stable work, wide measurement range and other advantages;
  • Sensing elements use a unique protective mechanism that can prevent condensate and impurities disturbance, which greatly improves the long-term stability of sensing elements, extends the  calibration cycle  of detector and the sensor service life effectively;
  • It adopts widely used USB charging mode,and the recorded data can be read through the USB port;
  • It adopts full-function remote control. By infrared remote control, you can accomplish operating voltage setting for sensing elements, zero point adjustment of hardware and software, gas concentrations calibration,virtual value proofing output,test alarm function, sensors reset and all other operational control;
  • It uses 2.4-inch TFT color display, can change display color in real time according to the detected gas data;
  • With built-in 1W speaker,it could give the value of gas concentration by voice,easy to use;
  • With Wi-Fi network capability,it can transmit detected data to the control room and other monitor.

 

Technical Parameters

  • measuring gas O2:measuring range(0~30)% measuring error ±3. 0%
  • measuring gas CO:measuring range(0~100)×10-6 measuring error ±(1.5+2%);measuring range(100~500)×10-6 measuring error ±4%;measuring range >500×10-6 measuring error ±10%
  • measuring gas H2S:measuring range(0~49)×10-6 measuring error ±3×10-6;measuring range(50~100)×10-6 measuring error ±10%
  • measuring gas CH4:measuring range(0.00~1.00)% measuring error ±0.10%;measuring range(1.00~3.00)% measuring error ±10%;measuring range(3.00~4.00)% measuring error ±0.30%
  • measuring  temperature:  environment temperature,measuring range(0 ~100)℃ measuring error ±0. 3℃
  • measuring humidity: relative humidity,measuring range(0 ~100)%,measuring error ±2%RH